BHV Klaar

Fire extinguishers at work in the Netherlands: classes, labels and inspection rules

Required extinguishers in Dutch buildings must be serviced at least every two years (Bbl 6.35). Fire classes A–F, labels and lithium fires explained.

In Dutch workplaces, portable fire extinguishers that the building regulations require must be maintained and checked at least once every two years (article 6.35 of the Besluit bouwwerken leefomgeving, the Bbl). Which extinguishers you need follows from the building rules and your company's risk assessment, and each extinguisher is labelled with the fire classes it can handle: A for solids, B for liquids, C for gases, D for metals and F for cooking fats and oils.

This guide explains the rules and the Dutch labels, for facility managers and for employees who act as BHV officers.

Who decides which extinguishers you need

Two sets of rules meet here:

  • Building rules (Bbl). Since 1 January 2024 the Bbl contains the fire safety rules for buildings, replacing the old Building Decree. It sets when portable extinguishers or hose reels are required and how they must be maintained.
  • Working conditions rules. Under the Working Conditions Act, the employer must equip BHV officers properly. According to Business.gov.nl, the risk assessment (RI&E) determines what equipment is needed, and fire extinguishers are one of its examples.

So a building may have the extinguishers the Bbl requires, plus extra ones the RI&E calls for – a fat extinguisher in a staff kitchen, or CO2 near server equipment.

Maintenance and inspection

According to IPLO, the government's information point on the Environment and Planning Act:

Installation Rule Frequency / validity
Portable extinguishers required by the Bbl Maintenance and check of proper functioning (art. 6.35(1) Bbl) At least every 2 years
Fire hose reels Separate provision (art. 6.35(2) Bbl) See the Bbl
Fire alarm system, where required Inspection certificate under the CCV scheme (art. 6.32 Bbl) 3 years, or 1 year if automatic forwarding to the fire service is required
Evacuation alarm system, where required Inspection certificate (art. 6.33 Bbl) 3 years, or 1 year if forwarding is required
Automatic sprinkler system Inspection certificate (art. 6.36 Bbl) 1 year

The Bbl no longer refers to the NEN 2559 maintenance standard for extinguishers, but IPLO notes that working to that standard is generally still enough to meet the duty.

Reading the label

Every extinguisher shows letters for the fire classes it can fight. Look at the letters, not the colour.

Class Burning material Suitable agents
A Solids: wood, paper, textiles Water (mist), foam, powder
B Liquids and melting plastics: petrol, paint, spirits Foam, powder, CO2
C Gases: natural gas, propane Powder – and shut off the gas if safe
D Metals: magnesium, aluminium Special D powder
F Cooking oils and fats F (fat) extinguisher, lid, fire blanket

There is no class E in the Netherlands any more: electricity itself does not burn, as Radar points out. For electrical equipment, switch off the power if possible and use an extinguisher whose label allows use near live equipment. A CO2 extinguisher, recognisable by its black horn, leaves no residue but displaces oxygen, so be careful in small rooms. The Dutch fire service advises extinguishers of at least 2 kg, because smaller ones empty too quickly.

Lithium-ion batteries

E-bike batteries, laptops and power banks are a growing concern in offices and bicycle storage areas. A battery fire can keep heating itself and flare up again after it seems out, and the smoke is toxic. According to Kiwa, a regular extinguisher is not enough. Only extinguishers that pass the Dutch test method NTA 8133+A1 are considered suitable, and approved units carry a label with a test number. Even then, judge first whether it is safe to fight the fire at all.

What BHV officers are trained to do

In the NIBHV basic course, firefighting is assessed in three practical skills: checking and opening a door when fire is suspected, tackling a small fire in solid materials, and tackling a small liquid or fat fire, according to the NIBHV specification. The basic approach:

  1. Raise the alarm first.
  2. Fight the fire only if it is small and your escape route stays clear behind you.
  3. Pull the pin, approach low and with the airflow, aim at the base of the fire, use short bursts.
  4. Watch for re-ignition, and have any used extinguisher refilled.
  5. If it does not work quickly, leave and close the door.

A simple monthly walk-round

Facility managers and BHV officers can spot most problems in five minutes:

  • Is every extinguisher in its place, visible and not blocked by boxes or furniture?
  • Is the seal intact?
  • Is the last service date within two years?
  • Is the type right for the room – fat extinguisher in the kitchen, nothing water-based next to the fryer?
  • Are the signs above the extinguishers still visible?

Learn the Dutch words

Signs and labels are in Dutch: brandblusser (extinguisher), blusdeken (fire blanket), brandslanghaspel (hose reel), poeder (powder), schuim (foam). BHV Klaar's fire classes screen sets the classes and extinguishers side by side, with an English interface and Dutch content. For the bigger picture of company emergency response, read what BHV is.

BHV Klaar

Fire, evacuation, first aid and CPR – with an explanation for every answer.

Download on the App Store

Frequently asked questions

How often must fire extinguishers be inspected in the Netherlands?

Portable extinguishers required under the Dutch Building Decree (Bbl) must be maintained and checked at least once every two years (article 6.35 Bbl). Hose reels have their own provision in the same article.

Is NEN 2559 still mandatory?

The Bbl no longer refers to NEN 2559 for extinguishers, but according to the government's information point, following it is generally still sufficient to meet the maintenance and inspection duty.

Which extinguisher works on a lithium-ion battery fire?

A regular extinguisher is usually not enough. Only extinguishers that passed the Dutch test method NTA 8133+A1 are considered suitable; approved units carry a label with a test number. Keep your distance and call 112.

Sources

  1. Brandveiligheidsinstallaties bij gebruik van een bouwwerk — Informatiepunt Leefomgeving (IPLO)
  2. Company emergency response (BHV) — Business.gov.nl (RVO) (2025-09-12)
  3. Kan een brandblusser Li-ion-accu's blussen? NTA 8133+A1 — Kiwa (2025-06-11)
  4. Hoe kies je de juiste brandblusser? — Radar (AVROTROS)
  5. Specificatieblad bedrijfshulpverlener brandbestrijding en ontruiming (versie 1, 2019) — NIBHV (2019)

More articles